Frequently Asked Questions

WHERE SHOULD I FIT FLASHBACK ARRESTORS?

Optimum protection is achieved when flashback arrestors are fitted to both oxygen and fuel gas hoses at the regulator outlet and the inlet of the blowpipe. In fact, this configuration is a requirement of AS4839 and legislation in some states.

If flashback arrestors are only fitted to the torch end, then no protection is given to the cylinder supply and regulators in the event that a flashback occurs upstream from the torch end arrestors. This may occur as a result of damage to the hose or through loose connections.

Flashback arrestors installed at the torch end provide protection for the gas hose in the event of a flashback. By quenching the flame and containing the pressure front via the non return valve, unnecessary damage to the hose is avoided.

 

WHAT INFORMATION DO I NEED TO ORDER THE CORRECT REGULATOR?

Tesuco have a huge range of regulators available, suitable for many applications. To assist us with ensuring that the correct regulator is supplied for any given application the following information is required:

  • Type of Gas
  • Purity of the Gas Supply
  • Required Inlet and Outlet Pressure
  • Single or Dual Stage Pressure Regulation
  • Required Flow Rate, if available

Please Note: Any additional information with regards to other installed equipment or required specifications will enable us to supply the correct regulator for your requirements.

 

WHERE CAN I PURCHASE TESUCO PRODUCTS FROM?

Tesuco have a large distributor network that spans Australia, New Zealand, Papua New Guinea and Fiji with full access to our entire range of products. Please contact us for information regarding your nearest stockist of Tesuco products.

 

ARE TESUCO PRODUCTS COVERED BY A WARRANTY?

All Tesuco products are covered by a 1 year limited warranty against manufacturer's defect. Selected products are covered by a 5 year limited warranty. These warranties do not cover damage to products through misuse or mishandling. For full warranty details and terms and conditions of sale, please contact your Tesuco representative.

 

DO TESUCO PRODUCTS MEET AUSTRALIAN STANDARDS?

Where Australian Standards exist detailing the design specifications of equipment, Tesuco endeavours to ensure that all of their products comply with Australian Standards. In the event that Australian Standards do not exist, then we draw on International Standards as the reference for equipment design.